PLN P

PLN P

50-150 kW

The reduction of polluting emissions, whether directly related to the use of greenhouse gases or more indirectly related to emissions from the production of electricity used during the lifetime of a heat pump, is the first and most important pillar on which has based its Advanced Design solutions. This has led to the creation of , new range of air-water with total recovery units, natural refrigerant and multiscroll solutions with capacity from 50 to 150 kW. Its extremely wide operating range and high performance under all operating conditions make it the perfect answer to the need to phase out the use of fossil fuels for heating and cooling buildings.
  • Scroll compressor
  • Multi-purpose unit - 4-pipe system
  • Cooling / Heating
  • R290 refrigerant
  • Atex A3 gas leak detection

PLN P

50-150 kW

The reduction of polluting emissions, whether directly related to the use of greenhouse gases or more indirectly related to emissions from the production of electricity used during the lifetime of a heat pump, is the first and most important pillar on which has based its Advanced Design solutions. This has led to the creation of , new range of air-water with total recovery units, natural refrigerant and multiscroll solutions with capacity from 50 to 150 kW. Its extremely wide operating range and high performance under all operating conditions make it the perfect answer to the need to phase out the use of fossil fuels for heating and cooling buildings.
  • Scroll compressor
  • Multi-purpose unit - 4-pipe system
  • Cooling / Heating
  • R290 refrigerant
  • Atex A3 gas leak detection
PLN P
  • Scroll compressor
  • Multi-purpose unit - 4-pipe system
  • Cooling / Heating
  • R290 refrigerant
  • Atex A3 gas leak detection

Advanced Design Plus

  • Use of natural refrigerant R290 (GWP = 3)
  • Multi-scroll solutions
  • Very high seasonal efficiency values
  • Maximum temperature of the water produced 78°C
  • Water produced at 50°C with -20°C external air
  • Finned coil circuitry designed to ensure counter-current exchange between air and refrigerant in every operating mode.
  • Smart Grid Certification
  • Eurovent Certifications

Product advantages

  • Electronic expansion valve as standard
  • High configurability and wide availability of accessories
  • On-board hydronic kit with 4 pumps and 1 buffer tank
  • Advanced logics for securing the unit in the event of refrigerant leaks

Available versions

  • 7 models
  • Multi-purpose version with total heat recovery for 4 pipes systems
  • Low noise acoustic configurations

Technical specifications

Find how an advanced design solution is born: advanceddesign.galletti.com

PLN P is the new Galletti range of multipurpose units with total recovery air-cooled, for outdoor installation equipped with multi-scroll solutions and characterised by the use of R290 refrigerant. R290 (Propane) is a natural refrigerant capable of guaranteeing one of the lowest GWPs on the market, equal to only 3. This GWP value ensures the PLN P range complies with the gradual reduction of emissions due to the use of greenhouse gases emissions required by the F-GAS regulation.

The range consists of 7 models with cooling capacities from 50 to 150 kW, suitable for 4-pipe system applications. Using solutions with multiple compressors on the same circuit, in addition to adjusting the power output to the actual thermal load, optimizes performance during partial load operation. This allows for achieving seasonal efficiency ratings among the highest in the HVAC market: SCOP up to 4.00 and SEER up to 5.00.

Furthermore, another distinctive advantage of the <pimdata/> range is its multipurpose configuration with total heat recovery, which allows for simultaneous summer and winter heating needs with a single solution. This feature optimizes the system's overall energy efficiency, reducing the need for additional systems and ensuring consistent comfort year-round.

The use of top quality components at the cutting edge of technology in the cooling, hydraulic, and electrical systems makes <pimdata/> multipurpose units state of the art in terms of efficiency, reliability, and operating limits. In fact, the ability to produce water up to 78°C, and full load operation with external air from -20°C to 48°C. With outside air temperatures of -20°C, the production of hot water at 50°C is still possible.

The range allows high configurability from an acoustic and hydraulic point of view, having ample accessories designed to meet installation needs characterized by reduced overall dimensions: without increasing the size it is possible to provide on board the storage tank and up to a maximum of four hydraulic pumps.

Advanced control, which is always provided across the entire range, allows continuous monitoring of operating parameters, advanced regulation logics, and connectivity and the management of advanced procedures for making the unit safe in the event of refrigerant leaks (A3).

Related documents and files

Technical details PLN - EN

Size: 12,044 MB

Technical details PLN - EN

Installation manual - EN

Size: 6,812 MB

Installation manual - EN

technical manual - EN

Size: 3,086 MB

technical manual - EN

Service center

Find the nearest service center

Find your local agent

We have several customized packages for your property. Fill out the form with the required details and we will contact you.

Request information

Click here and fill the form to ask for information on PLN P

Request more information